English (US). 1-Feb kB. Powerware UPS ( kVA) Installation and Operation Manual for UPS with serial number 7th digit at B. English (US). These efficiencies are for guidance only. Actual unit and system efficiencies will vary based on site design/conditions and environmental parameters. Parallel. UPS output power rating (0,9 p.f.). kVA, 40, 60, 80, , , kW, 36, 54, 72, 90, , General. Efficiency in double conversion mode (full load), 94%.

Author: Feran Goltirn
Country: Bahrain
Language: English (Spanish)
Genre: Science
Published (Last): 27 December 2009
Pages: 379
PDF File Size: 20.10 Mb
ePub File Size: 14.7 Mb
ISBN: 118-8-82826-433-4
Downloads: 27557
Price: Free* [*Free Regsitration Required]
Uploader: Malakinos

UPS | Energy Efficient | | Eaton

Software, eatn, and applications. In the event of a utility power failure, there is no delay transferring to backup power. When an existing UPS is exceeding capacity but has no room to expand, or when the service contract is expiring, the existing UPS can be removed and replaced with a that offers more power in less space.

With a transformerless design, Eaton UPS solutions meet or exceed virtually all floor loading standards. Each parallel unit operates with its own battery string — if any unit goes offline or is taken down for maintenance, the remaining units support the load fully with their battery capabilities. Energy Saver System High efficiency options reducing costs and wasted energy The waton delivered excellent energy efficiency since its introduction to the market, helping facilities save thousands upe energy costs over traditional UPS designs.

Even when presented with the most severe power problems, power output remains stable with the BlueGrass data center success story English US.

Paylocity English US. Register your UPS Register your product with us. ESS and estimated savings.

Eaton has approximately 96, employees eatom sells products to customers in more than countries. Now with the available Energy Saver System ESSthe achieves over 99 percent efficiency no matter how large or small the load.

Power factor PF describes the slight phase shift between voltage applied to a circuit and current that the circuit draws in response to the applied voltage. Click here for efficiency chart. The load share control algorithms maintain adjustments to variations in the output power requirements.

  AWID LR-2000 PDF

Eaton offers startup, warranty and additional services for Eaton UPS units. Kleinschmidt success story English.

Automotive company puts the brakes on power issues with English US. Eaton UPS brochure. These components may even create frequencies other than the fundamental applied frequency 60 Hz.

Eaton Model kVA volt – Refurbished UPS

Your best defense against Downtime! Learn more about the service offered. As a result, the transfers maximum power between the source and protected load and is exceptionally compatible with multiple power sources, especially auxiliary generators. Output voltage THD is held within two percent of nominal specification for linear loads, within five percent for non-linear loads—making the ideal for supporting equipment that is sensitive to a distorted voltage input as a result of harmonic loads.

Eaton is dedicated to improving the quality of life and the environment through the use of power management technologies and services. In all paralleling configurations, each UPS module operates independently yet is completely synchronized with the others. Canada Site Map Change Country.

Success Story 9×55, The ezton connectivity card options can be installed at any time: Unlike other paralleling techniques, there is no system-level single point of eatoj Hot Sync systems are capable of paralleling for both redundancy and capacity By using a peer configuration as opposed to a master-slave configuration, Hot Sync ensures that each module is operating independently No added circuitry or components are required to be switched in to operate in parallel With thousands of eagon systems installed globally, Hot Sync is a proven technology The output of multiple UPSs remains in phase so that static transfer switches connected between the separate distribution paths may change state seamlessly when necessary Each parallel unit operates with its own battery 93390 — if any unit goes offline or is taken down for maintenance, the remaining units support the eagon fully with their battery capabilities.

  6EP1437 3BA00 PDF

Being a pre-wired, integrated module, the saves time and cost of installation and cabling expenses because of standard top or bottom entry design. Powerware Hot Sync wireless paralleling technology for capacity or redundancy. Unlike traditional “eco” modes, ESS is not just a utility bypass. Stronger power performance A double-conversion UPS that resolves utility power problems and supplies clean, continuous, uninterruptible power to connected equipment.

Press Release s. Two communications bays standard. Eaton helps Chicago thwart potential disaster English US.

Eaton 9390 UPS

Low output THD provides clean pure power to operate the load safely and efficiently Complete line of raton accessories Battery cabinets Integrated distribution cabinets Integrated accessory cabinets. Whether you’re selecting a UPS for a branch office, manufacturing floor, medical facility, or data upd, there’s a model that delivers just the right combination of performance and price for your needs. The UPS offers innovative technologies to maximize the health and service life of its internal and external batteries:.

The has delivered excellent energy efficiency since its introduction to the market, helping facilities save thousands in energy costs over traditional UPS designs. The offers the smallest footprint of any UPS in its class—35 to 50 percent smaller than competitive units. Eaton’s TAA compliant products. To address these concerns for reliability — the degree of autonomy and the complexity of implementation — Hot Sync combines digital signal processing and an advanced control algorithm to provide automatic load sharing and selective tripping in a parallel system, as well as complete autonomy of the modules and a skillfully simple implementation.